| Features |
 |
Call to residential station |
 |
Digital display shows name of resident & room number |
 |
Monitoring a Video entrance station (audio) |
 |
Receive all Entrance station call-ins (Reception mode function) |
 |
Absence call-in memory stored with Callback |
 |
Option
Doorbell at door with different call tone
User-optional device can be controlled with SERVICE button, such as -light on and off at entry way to elevator |
 |
Receive a Panic call from apartment station |
|
 |
 |
| |
| Specifications (GH-MK) |
 |
| Power source |
DC 24V, supplied by PS-2410LD, PS-2410DIN |
 |
| VFD display |
Max. 16 letters for names; English, French, German, Spanish & Dutch |
 |
| Wiring |
2 single-pair cables |
 |
| Type of cable |
2-conductor cable solid copper & non-braided, polyethyleen insulation, 0.65mm dia.~1.0mm dia. |
 |
| Mounting |
Wall-mounting or Desk-top mounting on GFW-S |
 |
| Housing |
Fire-retardant plastic |
 |
|
|
|
|
|
|
|
 |
 |
 |
 |
| Wiring distance |
 |
| |
 |
Distance (Diameter of wires) |
 |
| GH-BC, GH-VBC to Farthest Entrance station |
|
300m(0.8mm) |
 |
| GH-BC, GH-VBC to Farthest Video apartment station |
|
150m(0.8mm) Expandable 150m with additional GH-VBC & Power supply |
 |
| GH-BC, GH-VBC to Farthest Audio apartment station |
|
300m(0.8mm) |
 |
| GH-BC, GH-VBC to each Power supply |
|
5m(0.8mm) |
 |
| GH-RY to Entrance station |
|
300m(0.8mm) |
 |
| Accumulated Audio lines (R1, R2) Total wiring distance |
|
2,500m(0.8mm) |
 |
|
 |
| Type of Cable |
| 2-conductor cables solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. |
|
 |
 |
 |
| Specifications (GH-BC, GH-VBC) |
 |
| Power source |
DC 24V, supplied by PS-2410LD, PS-2410DIN |
 |
| Consumption |
900mA. |
 |
| Wiring |
Single-pair cable common |
 |
| Housing |
Fire-retardant plastic |
 |
| |
| Specifications (GH-4Z) |
 |
| Wiring |
Two Single-pair cables common |
 |
| Mounting |
DIN rail |
 |
| Housing |
Fire-retardant plastic |
 |
|
|
|
| |
|
|
|
|
 |
 |
|
| Features |
 |
Expandable to max. 500 Apartment stations, 16 Entrance stations, and 4 Security guard stations |
|
 |
 |
 |
 |
 |
| Specifications (GH-BCX, GH-VBX) |
 |
| Power source |
GH-BCX: DC24V, supplied by PS-2410DIN.
GH-VBX: Supplied from GH-BCX |
 |
| Wiring |
Single-pair cable common |
 |
| Mounting |
DIN rail |
 |
| Housing |
Fire-retardant plastic |
 |
|
|
|
| |
|
|
|
|
 |
 |
 |
 |
| Specifications (PS-2410DIN) |
 |
| Input voltage & Capacity |
230V AC, 50Hz |
 |
| Output voltage |
24V DC, 1A |
 |
|
|
|
| |
|
|