CONTROL-BOX FOR ELECTRONIC DIGITAL KEYS, KEYPADS AND PROXIMITY READERS
MAIN FEATURES:
|
 |
Power supply: from 11 to 30 V ac/dc |
 |
Current drain: 4 mA at 12 V. |
 |
1 relay: resistive load: 10A/30V dc. It’s not allowed to apply to relay’s contacts voltages
over 30 V dc or 24 V ac. On the contrary, please link an external relay. |
 |
Contact of relay: permanent or impulsive. |
 |
“Dead man” function |
 |
Maximum number of codes: 60 |
 |
State memory of the relay. |
 |
Output for LED on/off |
 |
Output for programme mode LED |
 |
Output for Tamper alarm function (30 sec.) |
 |
Possibility to enter program mode directly from keypad. |
 |
Maximum distance between keypad and control-box: 300 mt. |
Simplified instruction manual for DIGITEN – MICROTEN keypads use only
RELAY’S TIME SETTING
Shut down the power supply to the control-box.
Press the push-button CLEAR for the duration of relay’s contact.
Press and hold down CLEAR push-button and, in the same time, give power supply to the controller.
Hold down the push-button and count the flashes of the red LED on the control-box, considering that:
1st flash = bistable
2nd flash = dead man function (*)
3rd flash = 250 ms (minimum contact duration)
4th flash = 1 second
5th flash = 2 seconds and so on until a maximum time of 27 seconds.
Release the push button when the desired duration is gained.
(*) Dead man function = the relay stays attracted as long as the last digit of the code is pressed.
STORING ADDITIONAL CODES
In any time is always possible to add other codes into the memory of the control-box via Master code,
directly from the keypad.
|
 |
Enter Master code: the relay does not operate, the red LED flashes and the control-box enter in
programme mode. |
 |
Enter the new codes you want to store with the same number of digits of the Master code. |
 |
To exit programme mode enter a code already stored. |
ADDRESSED CODES ERASING
In any time it is always possible to erase a code from the memory of the control-box, via
Master code directly from the keypad.
|
 |
Enter Master code: the relay does not operate, the red LED flashes and the control-box
enter in programme mode. |
 |
Enter five zeros followed by the number the corresponds to the location’s code in the
memory. For example if the code you want to erase is 1234 and it is the 4th code you
have stored, operate as follow: enter Master code, then enter 000004. |
 |
Wait for 5 sec. without pressing any other push-button on the keypad. After that short time
the red LED flashes quickly and then flashes slowly. |
 |
It is possible to store a new code with same digits of the Master code, in the empty location
of the code you have just erased. |
 |
To exit programme mode enter a code already stored.
Anyway, the control-box will exit programme mode automatically when the 60th code is stored
(full memory) or when you shut down the power supply. |
TAMPER alarm output – Violet wire. It activates (closes to negative) at the 4th attempt (during a period
of 30 sec.) at tampering or after 8 sec. of continuous transmission .
To reset Tamper alarm, enter a valid code or wait for 30 sec.

|